SUJANA, I NENGAH (2010) TINJAUAN KAPASITAS STRUKTUR RANGKA KUDA-KUDA (Truss) DARI BAMBU LAMINASI DENGAN ALAT SAMBUNG BAUT. S1 thesis, Universitas Mataram.
Text
1. Halaman Judul.doc Restricted to Repository staff only Download (165kB) |
|
Text
2.a.Pengesahan Pembimbing.doc Restricted to Repository staff only Download (28kB) |
|
Text
5. Daftar Isi.doc Restricted to Repository staff only Download (42kB) |
|
Text
10. ABSTRACT.doc Restricted to Repository staff only Download (34kB) |
|
Text
Bab I.doc Restricted to Repository staff only Download (47kB) |
|
Text
BAB II.doc Restricted to Repository staff only Download (435kB) |
|
Text
BAB IV.doc Restricted to Repository staff only Download (281kB) |
|
Text
BAB V.doc Restricted to Repository staff only Download (33kB) |
|
Text
BAB III.doc Restricted to Repository staff only Download (53MB) |
|
Text
DAFTAR PUSTAKA.doc Restricted to Repository staff only Download (27kB) |
Abstract
Reseaches of structural bamboo, especially bamboo trusses have been conducted with satisfactory results. In practice, the bamboo trusses often experienced to be constructed due to enormous variety of bamboo profile, not only between different species but also between bamboo of same species and even from the same log. Howover, the problem has now been overcome by estabilishing glued-laminated bamboo. The purpose of this study is to examine the behaviour of laminated bamboo trusses with bolt conecction for roof suport. This study was commenced by examining the physical and mechanical properties of plain Petung bamboo. And the the mechanical property of glued-laminated bamboo has also been examined. The main objective of this study is to investigate load bearing capacity of laminated bamboo trusses with bolt conecction. The 3/8” diameter of bolts was employed in these connections. The specimen was positioned in a Loading Frame when a single vertical load was applied on the top of the trusses using Hidraulic Jack. The load and deflection were recorded using Transducer Indicator and Dial Gauge respectively. The result of the study indicate that the load bearing capacity of the structure wai in the range 1400 - 1600 kg. The correlation of load and deflection can be expressed y = 3,952 + 105,689x – 1,876x2, where y represent load (kg) and x represent deflection (mm). The result also indicated that the loading capacity was below the theoritical loads because in calculation theoritical load the laminated bamboowas considered as a structure timber. The failure pattern of the structure can be identified through shear failure and excessive deflection.
Item Type: | Thesis (S1) |
---|---|
Keywords (Kata Kunci): | laminated bamboo, truss, bolted connection, load bearing capacity. |
Subjects: | T Technology > T Technology (General) |
Divisions: | Fakultas Teknik |
Depositing User: | Imran SE |
Date Deposited: | 23 Apr 2019 03:39 |
Last Modified: | 23 Apr 2019 03:39 |
URI: | http://eprints.unram.ac.id/id/eprint/13532 |
Actions (login required)
View Item |